cn
Conducted Immunity Test System_CST 10200B
  • Conducted Immunity Test System_CST 10200B

Conducted Immunity Test System
CST 10200B

CST 10200B RF Conducted Immunity Tester is an integrated automatic test system specially developed for automotive electronic BCI tests. It is fully designed in compliance with standards including ISO 11452-4, IEC 61000-4-6 and other relevant standards.


Introduction

CST 10200B RF Conducted Immunity Tester is an integrated automatic test system specially developed for automotive electronic BCI tests. It is fully designed in compliance with standards including ISO 11452-4, GB/T 33014.4, IEC 61000-4-6, GB/T 17626.6 and other relevant standards.


Adopting a highly integrated design, it comes with a built-in signal generator, RF power amplifier and RF power meter, greatly reducing setup costs and system complexity. Built-in wide dynamic range power meter ensures real-time and precise monitoring, stable test procedures and reliable measurement results.


The whole test system, centrally controlled by EMC-S(BCI) software (This product requires the software for operation), can improve system scalability and test efficiency. Test results support one-click saving, printing and internal enterprise sharing.

 

System Setup


cst10200b.jpg


① Test Software: EMC-S(BCI)

② Main Unit: CST 10200B

③ Attenuator: AT200-3dB-1G-NF-NF-A

④ Attenuator: AT200-40dB-4G-NF-NF-A

⑤ Coaxial Load: TF80

⑥ Current Injection Clamp: BCIP-500

⑦ Balun Transformer: BCICF-500

Features

> Highly integrated design with built-in signal generator, RF power amplifier and power meter

> Built-in an internal wide dynamic range power meter for real-time and precise monitor

> Accurate traceable closed-loop test; optional current probe for closed-loop method

> High expandability, supports conducted immunity testing

> Automated test procedures double testing efficiency

> High-stability hardware configuration for worry-free long-term operation

> Support monitoring and overrange protection functions for temperature, VSWR and power

Standards
IEC Standards
ISO Standards
GB/T Standards
Specification
Technical Parameters
Signal Generator
Frequency9 kHz ~ 3 GHz
Frequency Resolution0.23 Hz
Frequency Temperature Stability±0.5 ppm
Harmonics≤ -30 dBc
Non-Harmonic≤ -50 dBc
Output Power120 dBm ~ 0 dBm:9 kHz ~ 500 kHz
120 dBm ~ +10 dBm:500 kHz ~ 3 GHz
Power Accuracy±1.0 dB
Resolution0.1 dB
Internal Modulation Source (LF)Sine wave: 0.1 Hz ~ 500 kHz
Square wave: 0.1 Hz ~ 20 kHz
Triangular wave/Sawtooth wave: 0.1 Hz ~ 100 kHz
Amplitude Modulation (AM)Modulation depth: 0% ~ 100%
Modulation frequency: 20 Hz ~ 1 MHz
Frequency Modulation (FM)Max Frequency Deviation: 5 MHz
Modulation frequency: 20 Hz ~ 1 MHz
Phase Modulation (ФM)Phase deviation range: 0° ~ 360°
Modulation frequency: 1 Hz ~ 1 MHz
Reptation Time200 ns ~ 160 s
Pulse Width100 ns ~ 85 s
Output PortN-Female
VSWR<1.5
Power Amplifier
Frequency10 kHz ~ 500 MHz
Output Power
(1 dB compression point)
>200 W
VSWR< 1.5
Output Impedance50 Ω
Output PortN-Female
Power Meter (Built-in 3-channel Power Meter)
Frequency9 kHz ~ 3 GHz
Measurement Range-60 dBm ~ +20 dBm
Measurement Accuracy±0.5 dB
Input PortN-Female
VSWR< 1.3
General Parameters
Accessories
Optional Accessories
1Test Software
(This series of products shall be used with this software)
Model: EMC-S(BCI)
A RF conducted immunity test software for the CST series; support Windows 10 and USB communication; enable remote calibration and test operations
测试软件-EMC-S-BCI
2AttenuatorModel: AT200-3dB-1G-NF-NF-A
Attenuation value: 3 dB
Power: 200 W
衰减器-AT200-3dB
3AttenuatorModel: AT200-40dB-4G-NF-NF-A
Attenuation value: 40 dB
Power: 200 W
衰减器-AT200-3dB
4Coaxial LoadModel: TF80
Impedance: 50 Ω
Power: 80 W
50 Ω负载 TF80
5Current Injection ClampModel: BCIP-500
Frequency: 2 kHz ~ 500 MHz
Power:
100 W (30 min cont.)
150 W (15 min cont.)
200 W (5 min cont.)
Connector type: N type
Inner diameter: 40 mm
Outer diameter: 127 mm
Height: 70 mm
电流注入BCIP
6Calibration FixtureModel: BCICF-500
Frequency: DC ~ 500 MHz
Impedance: 50 Ω
Inner diameter: 40 mm
Inner length: 80 mm
Inner width: 127 mm
Inner height: 135 mm
校准夹具BCICF-200
7Current Monitoring ClampModel: TWCM-500
Frequency: 1 kHz ~ 500 MHz
Inner diameter: 40 mm;

Outer diameter: 127 mm; 

Height: 40 mm

RF current: 2 A
Pulse current: 100 A
电流探头-TWCM-500
Standard Accessories

Power Cord, RF cable, Flat Grounding Wire, USB Cable, Attenuator,Fuse, User Manual

CST B Series Selection Guide
ModelPower Amplifier
Frequency1 dB Gain
CST 10200B10 kHz ~ 500 MHz53 dB ± 2 dB (200 W)
CST 20150B10 kHz ~ 400 MHz51.8 dB ± 1 dB (150 W)
CST 1075B100 kHz ~ 400 MHz48.5 dB ± 2 dB (75 W)
CST 10150B100 kHz ~ 400 MHz51.8 dB ± 2 dB (150 W)
Request a Quote
Interested in our products? Leave us a message, and our team will get back to you soon!
  • Search Engine
  • Industry Exhibition / Trade Show
  • Social Media
  • Online Advertisement
  • Industry Publication
  • Business Partner / Distributor
  • Colleague or Industry Contact
  • Existing Customer
  • Other
I agree to the  Privacy Policy.

If you have any questions, feel free to Contact Us!

Prev: Conducted Immunity Test System Next: Conducted Immunity Test System Back to list
Request a Quote Now
Conducted Immunity Test System
CST 10200B
  • Search Engine
  • Industry Exhibition / Trade Show
  • Social Media
  • Online Advertisement
  • Industry Publication
  • Business Partner / Distributor
  • Colleague or Industry Contact
  • Existing Customer
  • Other
Quote List0
Compare0
Selection
Top
Compary
Add up to 5 product comparisons for each type.
Only compare the currently expanded module.