cn
Common-Mode Conducted Disturbances Simulator_CDS 300
  • Common-Mode Conducted Disturbances Simulator_CDS 300

Common-Mode Conducted Disturbances Simulator
CDS 300

The CDS 300 is a common-mode conducted disturbance simulator with a frequency range of 0 Hz (DC) to 165 kHz and a max. output voltage of 300 V.


Introduction

The CDS 300 is a common-mode conducted disturbance simulator with a frequency range of 0 Hz (DC) to 165 kHz and a max. output voltage of 300 V.

The generator is controlled by CoreLab software, enabling quick and convenient functional tests

 

It complies with IEC/EN 61000-4-16, IEC 61000-4-19, IEC/EN 60255-22-7 and JJF 1245.4-2019...


Naming Rules:


naming rules.png

Features

> Integrated design

> Frequency range: DC ~ 165 kHz

> Test voltage up to 30 V from 10 Hz to 165 kHz; up to 300 V at DC, 16 Hz,50 Hz and 60 Hz

> Frequency step: linear, logarithmic, fixed

Standards
GB/T Standards
Other Standards
View All Standards
Specification
Technical Parameters
Output Specifications (Continuous Mode)
Test FrequencyDC, 16 Hz, 50 Hz, 60 Hz
Open-circuit Voltage1 V ~ 30 V
Signal Level(0.1-30) V RMS or DC
Test Level 11 V, continuous
Test Level 23 V, continuous
Test Level 310 V, continuous
Test Level 430 V, continuous
Output Impedance50 Ω ±10%
Total Harmonic Distortion< 10% (sine wave)
DC Ripple< 5%
Output Specifications (Short-term Mode)
Test FrequencyDC, 16⅔ Hz, 50 Hz, 60 Hz
Open-circuit Voltage10 V ~ 330 V
Signal Level(1~330) V RMS or DC
Test Level 110 V, duration 1 s
Test Level 230 V, duration 1 s
Test Level 3100 V, duration 1 s
Test Level 4300 V, duration 1 s
Output Impedance50 Ω ±10%
Phase Sync0°±5%
DC Ripple< 5%
Rise/Fall time1 μs ~ 5 μs
Output Specifications (15 Hz - 165 kHz)
Frequency Range10 Hz~165 kHz
Signal Level(0.1~30) V RMS
Test Level 11 V - 0.1 V - 1 V
Test Level 23 V - 0.3 V - 3 V
Test Level 310 V - 1 V - 10 V
Test Level 430 V - 3 V - 30 V
Output Impedance50 Ω±10%
Total Harmonic Distortion< 1% (sine wave)
Differential-mode Voltage Disturbance Test
Frequency Range2 kHz ~ 150 kHz
WaveformSine wave, total harmonic distortion < 5%
Open-circuit Voltage0.1 V ~ 20 V
Load Impedance10 Ω±30%
Differential-mode Current Disturbance Test
Frequency Range2 kHz ~ 150 kHz
Max. Current5 A
BNC Output10:1(0.1 V/A)
Load Impedance10 Ω ±0.3Ω
General Parameters
Accessories
Optional Accessories
1Coupling NetworkModel: CN 416M2/M3-32
EUT voltage rating: Single-phase 2-wire or 3-wire, 32 A, 250 V AC/DC
Test voltage range: DC ~ 300 V
Frequency: DC (162/3 Hz, 50 Hz, 60 Hz)
2 kHz~150 kHz
M3-32.png
2Coupling NetworkModel: CN 416M4N-32
EUT voltage rating: Three-phase 4-wire, L-G, 250 V AC/DC
Test voltage range: DC ~ 300 V
Frequency: DC (162/3 Hz, 50 Hz, 60 Hz)
2 kHz ~ 150 kHz
CN416M4N-32.png
3Coupling NetworkModel: CN 416M5-32
EUT voltage rating: Three-phase 5-wire, L-G, 250 V AC/DC
Test voltage range: DC ~ 300 V
Frequency: DC (162/3 Hz, 50 Hz, 60 Hz)
2 kHz ~ 150 kHz
CN416M5-32.png
4Coupling/Decoupling NetworkModel: CDN 416T2
Frequency: 2 kHz ~ 150 kHz
Number of lines: 2
Max. current: 0.5 A
Max. voltage: AC 150 V, DC 200 V
Connector type: Terminal block
CDN416T2.png
5Coupling/Decoupling NetworkModel: CDN 416T4
Frequency: 2 kHz ~ 150 kHz
Number of lines: 4
Max. current: 0.5 A
Max. voltage: AC 150 V, DC 200 V
Connector type: Terminal block
CDN416T4.png
6Coupling NetworkModel: CDN 416T8
Frequency: 2 kHz ~ 150 kHz
Number of lines: 8
Max. current: 0.5 A
Max. voltage: AC 150 V, DC 200 V
Connector type: Terminal block
CDN416T8.png
7Coupling/Decoupling NetworkModel: CDN 419M3-32
EUT voltage rating: Single-phase 3-wire, 32 A, 250 V AC/DC
Frequency: 2 kHz ~ 150 kHz
CDN419M3-32.png
8Coupling/Decoupling NetworkModel: CN 419M4N-32
EUT voltage rating: Three-phase 4-wire, 32 A, L-G, 250 V AC/DC
Frequency: 2 kHz ~ 150 kHz
CN419M4N-32.png
9Coupling NetworkModel: CN 14598-19
Max. EUT voltage: 250 V AC
Max. EUT current: 32 A
CN14598-19.png
10Isolation TransformerConfiguration can be selected according to the power rating of single-phase or three-phase power supply chosen by customers. It is applied to coupling and decoupling waveform tests.
11CoreLab Immunity Test SoftwareSupport Windows 7/8/10 /11;
Support Ethernet Interface;
Support sequence test, easy to operate, generate and export test report.
CoreLab.png
12Differential Mode Current Test ModuleModel: WCT 20
Frequency: 2 kHz ~ 150 kHz
Max. current: 5 A
Max. voltage: less than 22 V
Impedance: 1 Ω±0.3 Ω
WCT-20.png
13Differential Mode Current Test ModuleModel: R419-10
Resistance: 10 Ω
14Differential Mode Current Test ModuleModel: RJJF-100
Resistance: 100 Ω
15Balanced-Unbalanced Impedance ConverterModel: Balun 50/10
Characteristic impedance: 50 Ω / 10 Ω
Frequency: 2 kHz ~ 150 kHz
Max. input voltage (Vpp): 400 V
Balun-50-10.png
Standard Accessories

User Manual, Test Cable, Fuse, Grounding Cable, RF Cable, Network Cable,Power Cord

Request a Quote
Interested in our products? Leave us a message, and our team will get back to you soon!
  • Search Engine
  • Industry Exhibition / Trade Show
  • Social Media
  • Online Advertisement
  • Industry Publication
  • Business Partner / Distributor
  • Colleague or Industry Contact
  • Existing Customer
  • Other
I agree to the  Privacy Policy.

If you have any questions, feel free to Contact Us!

Prev: Common-mode Conducted Immunity Coupling/Decoupling Network Next: None Back to list
Request a Quote Now
Common-Mode Conducted Disturbances Simulator
CDS 300
  • Search Engine
  • Industry Exhibition / Trade Show
  • Social Media
  • Online Advertisement
  • Industry Publication
  • Business Partner / Distributor
  • Colleague or Industry Contact
  • Existing Customer
  • Other
Quote List0
Compare0
Selection
Top
Compary
Add up to 5 product comparisons for each type.
Only compare the currently expanded module.