cn
Conducted Immunity Test System_CST 20150E
  • Conducted Immunity Test System_CST 20150E

Conducted Immunity Test System
CST 20150E

The CST 20150E conducted immunity test system is an integrated automatic test system in accordance with IEC 61000-4-39, IEC 61000-4-6, YY 9706.102, designed for radiated fields in close proximity - immunity test, conducted immunity test, and supporting pulse and sinusoidal injection tests for power supply lines of electric vehicles. 

Introduction

The CST 20150E conducted immunity test system is an integrated automatic test system in accordance with IEC 61000-4-39, IEC 61000-4-6, YY 9706.102, designed for radiated fields in close proximity - immunity test, conducted immunity test, and supporting pulse and sinusoidal injection tests for power supply lines of electric vehicles. Adopting a highly integrated design, it comes with a built-in signal generator, RF power amplifier and RF power meter, greatly reducing setup costs and system complexity. Built-in wide dynamic range power meter ensures real-time and precise monitoring, stable test procedures and reliable measurement results. Output frequency range of the test system is 9 kHz ~ 230 MHz.


The whole test system, centrally controlled by EMC (-4-39) and EMC (-4-6) software (this product requires the software for operation), can improve system scalability and test efficiency. Test results support one-click saving, printing and internal enterprise sharing.


9 kHz ~ 150 kHz System Setup —Radiated fields in close proximity:


9 kHz~150 kHz.png

①  Main Unit: CST 20150E

②  Attenuator: AT150-3dB-6G-NF-NF-B

③  Magnetic Field Probe: FESP 5134-40

④  Probe Holder: LoopHolder50

⑤  Radiating Loop: FESP 5132

⑥  PC software: EMC(-4-39)


150 kHz~26 MHz System Setup —Radiated fields in close proximity:


150 kHz~26 MHz.png

①  Main Unit: CST 20150E

②  Attenuator: AT150-3dB-6G-NF-NF-B

③  Matching Network: NFCN 1356

④  Magnetic Field Probe: FESP 5134-1

⑤  Probe Holder: LoopHolder 5164-39

⑥  Radiating Loop: HFRA 5164

⑦ PC software: EMC(-4-39)


Conducted Immunity Test System Setup:


setup.png

setup1.png


Features

> Highly integrated design with built-in signal generator, RF power amplifier and power meter

> Built-in an internal wide dynamic range power meter for real-time and precise monitor

> Support high-precision closed-loop test with traceable results

> Automated test procedures double testing efficiency

> High-stability hardware for worry-free long-term operation

> Support monitoring and overrange protection functions for temperature, VSWR and power


Standards
Other Standards
Specification
Technical Parameters
RF Signal Generator
Frequency9 kHz ~ 3 GHz
Frequency Resolution0.23 Hz
Frequency Temperature Stability± 0.5 ppm
Harmonics≤-30 dBc
Non-Harmonic≤-50 dBc
Output Power-120 dBm ~ 0 dBm (9 kHz ~ 500 kHz)
-120 dBm ~ +10 dBm (500 kHz ~ 3 GHz)
Power Accuracy±1.0 dB
Resolution0.1 dB
Internal Modulation Source (LF)Sine wave: 0.1 Hz ~ 500 kHz
Square wave: 0.1 Hz ~ 20 kHz
Triangular wave/Sawtooth wave: 0.1 Hz ~ 100 kHz
Amplitude Modulation (AM)Modulation depth: 0% ~ 100%
Modulation frequency: 1 Hz ~ 25 kHz
Frequency Modulation (FM)Max Frequency Deviation: 5 MHz
Modulation frequency: 1 Hz ~ 25 kHz
Phase Modulation (ФM)Phase deviation range: 0° ~ 360°
Modulation frequency: 1 Hz ~ 25 kHz
Output PortN-Female
VSWR<1.5
Power Amplifier
Frequency9 kHz ~ 230 MHz
Output Power(1 dB compression point)>150 W
VSWR< 1.5
Output Impedance50 Ω
Output PortN-Female
Power Meter
Frequency9 kHz ~ 6 GHz
Measurement Range-60 dBm ~ +20 dBm
Measurement Accuracy±0.5 dB
Input PortN-Female
VSWR< 1.3
General Parameters
Accessories
Radiated Fields in Close Proximity – Immunity Test
1Test Software
(This series of products shall be used with this software.)
Model: EMC (-4-39)
A RF conducted immunity test software for the CST series; support Windows 10 and USB communication; enable remote calibration and test operations
EMC(-4-39).png
2AttenuatorModel:
AT150-3dB-6G-NF-NF-B
Frequency: DC ~ 6 GHz
Attenuation value: 3 dB
Power: 150 W
AT150-3dB-6G-NF-NF-B.png
3Radiating LoopModel: HFRA 5164
Frequency: 10 kHz ~ 120 MHz
Diameter: 100 m
HFRA 5164.png
4Matching NetworkModel: NFCN 1356
Frequency: 13.56 MHz
Impedance: 50 Ω
Max. Power: 15 W
Magnetic field strength: 15 A/m
Interface: BNC
NFCN 1356.png
5Probe HolderModel: LoopHolder 5164-39
the holder of FESP 5134-1
LoopHolder 5164-39.png
6Magnetic Field ProbeModel: FESP 5134-1
Frequency: 10 kHz ~ 400 MHz
Diameter: 40mm
Turn: 1
FESP 5134-1.png
7Radiating LoopModel: FESP 5132
Frequency: DC-150 kHz
Diameter: 120 mm
FESP 5132.png
8Magnetic Field ProbeModel: FESP 5134-40
Frequency: 5 Hz ~ 250 kHz
Diameter: 40 mm
FESP 5134-40.png
9Probe Holder

Model: LoopHolder50

the holder of FESP 5134-40

LoopHolder50.png
Conducted Immunity Test
Standard Accessories

Power Cord, RF Cable, Grounding Wire, Test Cable, USB Cable, Attenuator, Snap-on Ferrite Core, Fuse, User Manual

Series Model Comparison
ModelPower Amplifier Parameters
Frequency1 dB Gain
CST 1075100 kHz ~ 230 MHz48.5 dB ± 2 dB (75 W)
CST 10150100 kHz ~ 230 MHz51.8 dB ± 2 dB (150 W)
CST 1075E100 kHz ~ 230 MHz48.5 dB ± 2 dB (75 W)
CST 20150E9 kHz ~ 230 MHz51.8 dB ± 2 dB (150 W)
Request a Quote
Interested in our products? Leave us a message, and our team will get back to you soon!
  • Search Engine
  • Industry Exhibition / Trade Show
  • Social Media
  • Online Advertisement
  • Industry Publication
  • Business Partner / Distributor
  • Colleague or Industry Contact
  • Existing Customer
  • Other
I agree to the  Privacy Policy.

If you have any questions, feel free to Contact Us!

Prev: None Next: Conducted Immunity Test System Back to list
Request a Quote Now
Conducted Immunity Test System
CST 20150E
  • Search Engine
  • Industry Exhibition / Trade Show
  • Social Media
  • Online Advertisement
  • Industry Publication
  • Business Partner / Distributor
  • Colleague or Industry Contact
  • Existing Customer
  • Other
Quote List0
Compare0
Selection
Top
Compary
Add up to 5 product comparisons for each type.
Only compare the currently expanded module.