cn
Conducted Immunity Test System_CST 1075E
  • Conducted Immunity Test System_CST 1075E
  • Conducted Immunity Test System_CST 1075E

Conducted Immunity Test System
CST 1075E

The CST 1075E conducted immunity test system is an integrated automatic test system designed in accordance with IEC/EN 61000-4-6 and medical industry standard YY 9706.102. 

Introduction

The CST 1075E conducted immunity test system is an integrated automatic test system designed in accordance with IEC/EN 61000-4-6 and medical industry standard YY 9706.102. Adopting a highly integrated design, it comes with a built-in signal generator, RF power amplifier and RF power meter, greatly reducing setup costs and system complexity. Built-in wide dynamic range power meter ensures real-time and precise monitoring, stable test procedures and reliable measurement results.

 

The whole test system, centrally controlled by EMC (-4-6) software (this product requires the software for operation), can improve system scalability and test efficiency. Test results support one-click saving, printing and internal enterprise sharing.


System Setup


setup.png

setup1.png


Features

> Highly integrated design with built-in signal generator, RF power amplifier and power meter

> Built-in an internal wide dynamic range power meter for real-time and precise monitor

> Supports bulk current injection (with injection current clamp), current test method, and voltage test method (utilizing electromagnetic clamp and coupling/decoupling network)

> Automated test procedures double testing efficiency

> High-stability hardware for worry-free long-term operation

> Support monitoring and overrange protection functions for temperature, VSWR and power

> Modulation frequency is 1 Hz

Standards
IEC Standards
GB/T Standards
EN Standards
Other Standards
View All Standards
Specification
Technical Parameters
RF Signal Generator
Frequency9 kHz ~ 3 GHz
Frequency Resolution0.23 Hz
Frequency Temperature Stability± 0.5 ppm
Harmonics≤-30 dBc
Non-Harmonic≤-50 dBc
Output Power-120 dBm ~ 0 dBm (9 kHz ~ 500 kHz)
-120 dBm ~ +10 dBm (500 kHz ~ 3 GHz)
Power Accuracy±1.0 dB
Resolution0.1 dB
Internal Modulation Source (LF)Sine wave: 0.1 Hz ~ 500 kHz
Square wave: 0.1 Hz ~ 20 kHz
Triangular wave/Sawtooth wave: 0.1 Hz ~ 100 kHz
Amplitude Modulation (AM)Modulation depth: 0% ~ 100%
Modulation frequency: 1 Hz ~ 25 kHz
Frequency Modulation (FM)Max frequency deviation: 5 MHz
Modulation frequency: 1 Hz ~ 25 kHz
Phase Modulation (ФM)Phase deviation range: 0° ~ 360°
Modulation frequency: 1 Hz ~ 25 kHz
Output PortN-Female
VSWR<1.5
Power Amplifier
Frequency100 kHz ~ 230 MHz
Output Power(1 dB compression point)>75 W
VSWR< 1.5
Output Impedance50 Ω
Output PortN-Female
Power Meter
Frequency9 kHz ~ 3 GHz
Measurement Range-60 dBm ~ +20 dBm
Measurement Accuracy± 0.5 dB
Input PortN-Female
VSWR< 1.3
General Parameters
产品配件
Optional Accessories
1Test Software
(This series of products shall be used with this software.)
Model: EMC (-4-6)
A RF conducted immunity test software for the CST series; support Windows 10 and USB communication; enable remote calibration and test operations

Test Software

2AttenuatorModel: AT80-6dB-4G-NF-NF
Frequency: DC ~ 4 GHz
Attenuation value: 6 dB
Power: 80 W

Attenuator

3Coupling/Decoupling NetworkCDN M Series
CDN T Series
CDN AF Series

CDN

4150 Ω to 50 Ω CDN Calibration AdapterModel: CDN 100KIT
Insertion loss: 9.5 dB ± 0.5 dB
Number: 2

150 Ω to 50 Ω Calibration Adapter

5Electromagnetic ClampModel: EM CL100
Frequency: 100 kHz ~ 1GHz
Power: 100 W (5 min cont.)
Directivity: ≥ 10 dB above 0.1 MHz
(including 150 Ω to 50 Ω calibration adapter)

Electromagnetic Clamp


6Current Injection ClampModel: BCIP-500
Frequency: 2 kHz ~ 500 MHz
Power: 100 W (30 min cont.)
150 W (15 min cont.)
200 W (5 min cont.)
Interface: N
Inner Diameter: 40 mm
Outer Diameter: 127 mm
Height: 70 mm

Current Injection Clamp

7Current Injection Clamp Calibration FixtureModel: BCICF-500
Frequency: DC ~ 500 MHz
Characteristic Impedance: 50 Ω
Inner Body Diameter: 40 mm
Inner Length: 80 mm
Inner Width: 127 mm
Inner Height: 135 mm

Current Injection Clamp Calibration Fixture

8150 Ω to 50 Ω Calibration AdapterModel: BCI 100KIT
Insertion loss: 9.5 dB ± 0.5 dB
Number: 2

150 Ω to 50 Ω Calibration Adapter

Standard Accessories

Power Cord, RF Cable, Grounding Wire, Test Cable, USB Cable, Attenuator, Snap-on Ferrite Core, Fuse, User Manual

Series Model Comparison
ModelPower Amplifier Parameters
Frequency1 dB Gain
CST 1075100 kHz ~ 230 MHz48.5 dB ± 2 dB (75 W)
CST 10150100 kHz ~ 230 MHz51.8 dB ± 2 dB (150 W)
CST 1075E100 kHz ~ 230 MHz48.5 dB ± 2 dB (75 W)
CST 20150E9 kHz ~ 230 MHz51.8 dB ± 2 dB (150 W)
Request a Quote
Interested in our products? Leave us a message, and our team will get back to you soon!
  • Search Engine
  • Industry Exhibition / Trade Show
  • Social Media
  • Online Advertisement
  • Industry Publication
  • Business Partner / Distributor
  • Colleague or Industry Contact
  • Existing Customer
  • Other
I agree to the  Privacy Policy.

If you have any questions, feel free to Contact Us!

Prev: Conducted Immunity Test System Next: Coupling/Decoupling Network Back to list
Request a Quote Now
Conducted Immunity Test System
CST 1075E
  • Search Engine
  • Industry Exhibition / Trade Show
  • Social Media
  • Online Advertisement
  • Industry Publication
  • Business Partner / Distributor
  • Colleague or Industry Contact
  • Existing Customer
  • Other
Quote List0
Compare0
Selection
Top
Compary
Add up to 5 product comparisons for each type.
Only compare the currently expanded module.