cn
Airborne DC Power Characteristic  Test System_PDG 54Cxx Series
  • Airborne DC Power Characteristic  Test System_PDG 54Cxx Series

Airborne DC Power Characteristic Test System
PDG 54Cxx Series

The PDG 54Cxx Airborne DC Power Characteristic Test System supports DC 14 V, 28 V, 270 V, 540 V test, in compliance with MIL-STD-704F, DO160 S16/S18, HB 20326.7/8, GJB 181-86 and GJB 181A/B. Its total voltage distortion is below 0.3% under all load conditions, with frequency coverage from DC to 200 kHz.

Introduction

The PDG 54Cxx Airborne DC Power Characteristic Test System supports DC 14 V, 28 V, 270 V, 540 V test, in compliance with MIL-STD-704F, DO160 S16/S18, HB 20326.7/8, GJB 181-86 and GJB 181A/B. Its total voltage distortion is below 0.3% under all load conditions, with frequency coverage from DC to 200 kHz.


Adopted real-time processor technology, the system is equipped with high-performance PC and Corelab test software. It enables arbitrary waveform editing to simulate complex waveforms, and provides preset waveforms and EMC and aerospace standard test items. The software also supports automatic test report generation.


Naming Rules

Naming Rules.png

Features

> Support harmonics output

> Support ripple closed-loop test

> Full-power four-quadrant power supply

> Adaptive remote compensation function

> Wide frequency range: DC ~ 200 kHz

> Max. test current 240 A (higher current ratings are available on request)

> Max. output power 120 kW (higher current ratings are available on request)

> Voltage and current monitoring and protection

> Ethernet RJ45 interfaces for PC remote control and printing test reports

> Built-in arbitrary waveform generator for any complex waveform editing


Standards
GJB Standards
Application Areas
Specification
Technical Parameters
ModelPDG 54C12
DC 270 V and 540 V Test System
Max. DC Voltage1,500 V
Output Power60 kW
Max. DC Current120 A
DC Voltage Accuracy± (0.01% + 0.05% F.S.*1)
DC Current Accuracy± (0.1% + 0.2% F.S.*1)
DC 14 V and DC 28 V Test System
Max. DC Voltage80 V
Output Power2.4 kW
Max. DC Current30 A
DC Voltage Accuracy± (0.2% + 0.2% F.S.*2)
DC Current Accuracy± (0.2% + 0.5% F.S.*2)
Note:
*1: F.S. (full scale) refers to max. voltage 1,500 V and max. current 120 A for DC 270 V and 540 V test system.
*2: F.S. (full scale) refers to max. voltage 80 V and max. current 30 A for DC 14 V and DC 28 V test system.
ModelPDG 54C24
DC 270 V and 540 V Test System
Max. DC Voltage1,500 V
Output Power120 kW
Max. DC Current240 A
DC Voltage Accuracy± (0.01% + 0.05% F.S.*3)
DC Current Accuracy± (0.1% + 0.2% F.S.*3)
DC 14 V and DC 28 V Test System
Max. DC Voltage80 V
Output Power2.4 kW
Max. DC Current30 A
DC Voltage Accuracy± (0.2% + 0.2% F.S.*4)
DC Current Accuracy± (0.2% + 0.5% F.S.*4)
Note:
*3: F.S. (full scale) refers to max. voltage 1,500 V and max. current 240 A for DC 270 V and 540 V test system.
*4: F.S. (full scale) refers to max. voltage 80 V and max. current 30 A for DC 14 V and DC 28 V test system.
Voltage/Current Setting Resolution0.01 V/0.01 A
Voltage/Current Display Resolution0.01 V/0.01 A
Harmonics Voltage0 V ~ 20 V
Harmonics Voltage Setting Resolution0.001 V
Harmonics Voltage Display Resolution0.001 V
Harmonics Frequency1 kHz ~ 50 kHz (higher frequencies are available on request)
Harmonics Frequency Setting Resolution0.001 Hz
Harmonics Frequency Display Resolution0.001 Hz
Total Voltage Harmonic Distortion (THDv)<0.3%
Ripple Noise @20MHz bandwidthVPP≤ 2.4 V
Vrms≤ 0.4 V
General Parameters
Accessories
Standard Accessories

Power Cord, Test Cable, User Manual, Flat Grounding Wire, Fuse

Request a Quote
Interested in our products? Leave us a message, and our team will get back to you soon!
  • Search Engine
  • Industry Exhibition / Trade Show
  • Social Media
  • Online Advertisement
  • Industry Publication
  • Business Partner / Distributor
  • Colleague or Industry Contact
  • Existing Customer
  • Other
I agree to the  Privacy Policy.

If you have any questions, feel free to Contact Us!

Prev: None Next: Airborne DC Power Characteristic Test System Back to list
Request a Quote Now
Airborne DC Power Characteristic Test System
PDG 54Cxx Series
  • Search Engine
  • Industry Exhibition / Trade Show
  • Social Media
  • Online Advertisement
  • Industry Publication
  • Business Partner / Distributor
  • Colleague or Industry Contact
  • Existing Customer
  • Other
Quote List0
Compare0
Selection
Top
Compary
Add up to 5 product comparisons for each type.
Only compare the currently expanded module.