The RWPN 6916TUL ring wave coupling/decoupling network provides complies with IEC/EN 61000-4-12 and UL 60730-1.
The RWPN 6916TUL ring wave coupling/decoupling network provides complies with IEC/EN 61000-4-12 and UL 60730-1. It is fully automatic three-phase coupling/decoupling function and is designed for use with the RWS 600 series simulator.
The RWPN 6916TUL supports EUT with a Max. load capacity of AC 690 V 16 A three-phase five-wire system. Other EUT voltage and current ratings can be customized according to customer requirements.
> EUT AC load capacity AC 690 V 16 A, three-phase five-wire
> EUT power supply automatic switching
> Test parameters such as test voltage, polarity and phase synchronization angle can be scheduled for fully automatic network switching
> Arbitrary phase angle superposition on any line