The AN 150C30F HV Artificial Network complies with ISO 21498-2:2021, ISO 21498-2:2024, MBN 11123 and VW 80300. It features a maximum full-range load capability of DC 1,500 V/300 A.
The AN 150C30F HV Artificial Network complies with ISO 21498-2:2021, ISO 21498-2:2024, MBN 11123 and VW 80300. It features a maximum full-range load capability of DC 1,500 V/300 A.
The AN 150C30F integrates impedance of 0 mΩ (direct mode)*1, 2*10 mΩ, 2*25 mΩ, 2*50 mΩ, 2*100 mΩ, 50 mΩ, 100 mΩ, and 200 mΩ, together with a 10 mF capacitor. With flexible switching between Standard Mode and Direct Mode, it meets diverse testing requirements for high-voltage components.
Test Setup

① PC software AutoLab
② Electric Vehicle HV Electrical Performance Comprehensive Tester EVTS Series
③ HV Artificial Network AN Series/ HV Test Device HTS Series
④ HV DC Short-Circuit Simulator HDSS Series
⑤ Wide-range Adjustable Pre-charging Test Device RC Series
⑥ Ripple Signal Generator RSG Series
⑦ Coupling Transformer TPT Series
⑧ Automotive Load Dump Simulator EVDG 20/ Electro-mobile Vehicles Pulse Disturbance Generator EVPG 20/ Electro-mobile Vehicles Pulse Disturbance Simulator EVPS Series
Equipment Connection

① PC software AutoLab
② Electric Vehicle HV Electrical Performance Comprehensive Tester EVTS 150C36
③ HV Artificial Network AN 150C30F
> Decoupling capacitor 10 mF, tolerance 0% ~ +10%
> Max. output voltage 1,500 V DC
> Max. current (full range): 300 A
> Dual modes, standard mode for HV component impedance networks; direct mode for direct connection tests without impedance networks
> Output impedance: 0 mΩ (direct mode)1, 2*10 mΩ, 2*25 mΩ, 2*50 mΩ, 2*100 mΩ, 50 mΩ, 100 mΩ, 200 mΩ
> Support capacitor voltage monitoring and display function
> Features overcurrent, overtemperature, low cooling water flow, cooling water overtemperature, and cooling water overpressure protection
> HV monitoring protection and automatic HV discharge
> Water cooling design for enhanced heat dissipation capability
> Built-in dehumidification module to effectively prevent condensation
Note: 0 mΩ (direct mode)1: Internal direct connection without decoupling capacitor, grounding capacitor, or output resistance.