New Professional Solution for Voltage Dips & Short Interruptions Testing up to 1500 V / 100 A
Efficient · Reliable · Safe & Controllable · Accurate Simulation of HV Grid Faults
Background
The 1500V AC voltage level has become a key development direction in new energy, industrial power, photovoltaic (PV), and energy storage applications, offering the benefits of high power transmission and low losses. Voltage variations caused by grid faults or load changes can easily lead to equipment failure, making rigorous voltage dip testing a critical safeguard for product reliability.
Technical Challenges
Testing systems for 1500V AC voltage dips, short interruptions, and voltage variations fill a technological gap in new energy (PV/storage), industrial power, and photovoltaic applications, supporting the validation of high‑power equipment in these fields. However, they also introduce challenges in insulation and arc control under high voltage and high current, precise simulation of voltage dips, and the coordination of automated testing with safety protection – mass production imposes stringent requirements on test accuracy and reliability.
Solution
3CTEST PFS 150100T1 Power Supply Fault Simulator
Defining test boundaries with standards, ensuring reliability through testing – designed to overcome the above technical challenges.

Standard Compliance: Meets the technical requirements of IEC 61000-4-34 and GB/T 17626.34
Realistic Simulation: Optimized arc suppression and waveform control technology for accurate grid fault simulation; strong surge tolerance for extreme operating conditions; eliminates waveform distortion under high voltage/current, easily meeting rigorous HV testing requirements
Precision Monitoring: Real‑time voltage and current acquisition – full visibility of test conditions
High Automation: CoreLab unified software platform – graphical interface · test case editing · parameter configuration · automatic execution · end‑to‑end automated testing and data traceability
Safe and Controllable: Multiple protection mechanisms + remote control, balancing test safety and efficiency
Main Technical Specifications
| AC 1500V Voltage Dip, Short Interruption and Voltage Variation Test System | |
| Model | Main Technical Specifications |
| Standards: IEC 61000-4-34, GB/T 17626.34 | |
| Max. EUT input voltage: 1500V AC, 50/60 Hz | |
| EUT voltage / current (customizable): 102 A | |
| Surge current withstand: >1000 A | |
| Interruption / dip levels: 0%, 40%, 70%, 80% | |
| Dip / interruption duration: 0.3 ~ 9999 cycles or 10 ms ~ 99999 ms | |
| Dip / interruption interval: 50 ms ~ 50000 ms | |
| Rise / fall time for dip / interruption: 1 μs ~ 50 μs @ 50 Ω | |
| Built‑in overcurrent, short‑circuit, overvoltage, overtemperature, surge, EFT, and ESD protection; safety ports allow flexible connection of external protection accessories (warning light, emergency stop button...) | |
| Detailed Technical Parameters (click to view) | |