The European edition of the common-mode disturbance test in the band from zero to 150 kHz addresses a range that European transmission and distribution practice makes important: the earth system carries the return current of every electrified railway, tramway, welding plant and large rectifier installation, and equipment connected to that system can be disturbed by voltages for which no other immunity test provides. The test is called up by the substation automation standards, by the standards for railway fixed installations and by the generic industrial immunity standard, which fix the level from the installation concerned. The European text reproduces the international continuously operating source and the coupling arrangements for d.c. power, a.c. power and signal ports, and it carries the foreword and annex that connect it to the directive. Because the disturbance is continuous, the acceptance criterion is normally a maximum permitted measurement error rather than a performance class.
The CN 416M4N-100 Coupling Network complies with IEC 61000-4-16, GB/T 17626.16 and other domestic and international standards.
The CN 416M5-100 Coupling Network complies with IEC 61000-4-16, GB/T 17626.16 and other domestic and international standards.
The CN 416M4N-32 Coupling Network complies with IEC 61000-4-16, GB/T 17626.16 and other domestic and international standards.
The CN 416M5-32 Coupling Network complies with IEC 61000-4-16, GB/T 17626.16 and other domestic and international standards.
The CN 416M4N-32(690V) Coupling Network complies with IEC 61000-4-16, GB/T 17626.16 and other domestic and international standards.
The CN 416M2/M3-32 Coupling Network complies with IEC 61000-4-16, GB/T 17626.16 and other domestic and international standards.
The CDN 416T4 (300 V) coupling/decoupling network complies with IEC 61000-4-16, GB/T 17626.16 and other domestic and international standards.
The CDN 416T2 (300 V) coupling/decoupling network complies with IEC 61000-4-16, GB/T 17626.16 and other domestic and international standards.
The CDS 300 is a common-mode conducted disturbance simulator with a frequency range of 0 Hz (DC) to 165 kHz and a max. output voltage of 300 V.
• Using the product inquiry function can help you quickly learn about the product's price and other related information.
• You can either inquire about a single product directly, or select multiple products to add to the inquiry bar and inquire about them together.
• How to make an inquiry





1. Using the product comparison function can help you find the target product you need for selection more quickly and easily.
2. You can add up to 5 products for comparison. Product models and parameters may vary across different series. It is recommended to compare products within the same series.
3. How to use the comparison bar.